Stainless Steel Pneumatic Turbine Vibrator

Description
The TV Stainless Steel Pneumatic Turbine Vibrator is comprised of a body section, one end plate having a right hand thread, and a detachable foot. Vibration is produced by the centrifugal force of the positive and negative unbalanced moments in the rotor. The rotor is supported on two heavy duty pre-lubricated matched sealed bearings. A special high performance grease ensures a long working life. The inner and outer raceways of the bearings are designed so that the bearings can easily be removed without using special tools.

Maximum temperature 120°C = 250°F.

Noise level range 60 to 75 dB.

Application
The TV SS range of turbine vibrators are suitable for use in the Food and Pharmaceutical industries and in hazardous areas where contact with non-ferrous materials, paint, or exhaust contaminated oil is not acceptable. No lubrication is required, but clean filtered air is essential.

These vibrators are extremely quiet, thus helping to conform with noise regulations.

On request can be supplied with ATEX certification
to ATEX 95 94/9/EC   Ex II 2 G & D    Zone 1, 2, 21, 22

Technical Data- 2 BAR - 30 PSI

Model

Vibration

Force

Air Consumption

VPM

N

Kg

lb

L/min

Cfm

TV-10SS

27,500

583

59

131

46

1.6

TV-16SS

17,000

1103

112

248

120

4.2

TV-25SS

12,000

1784

182

401

185

6.5

Technical Data- 4 BAR - 60 PSI

Model

Vibration

Force

Air Consumption

VPM

N

Kg

lb

L/min

Cfm

TV-10SS

35,000

946

96

213

80

2.8

TV-16SS

21,500

1764

180

397

200

7.0

TV-25SS

15,500

2977

304

669

325

11.4

Technical Data- 6 BAR - 90 PSI

Model

Vibration

Force

Air Consumption

VPM

N

Kg

lb

L/min

Cfm

TV-10SS

37,500

1086

111

244

112

3.9

TV-16SS

24,000

2198

224

494

290

10.2

TV-25SS

17,000

3581

365

805

455

16.0

Overall Size

Model

A

B

C

D

E

F

øG

mm

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

in

TV-10SS

49

1.93

55

2.17

38.1

1.50

30

1.18

68

2.68

6

0.24

7

0.28

TV-16SS

64

2.52

74

2.91

45.5

1.79

40

1.57

90

3.54

10

0.39

9

0.35

TV-25SS

78

3.07

88

3.46

55.5

2.19

50

1.97

104

4.09

10

0.39

11

0.43

Data obtained on a heavy laboratory test block. Frequency and force will decrease on a less rigid mount.